Products |
|
| |
| |
|
|
Temperature » Data Logger/Scanner » 8 - channel Data Logger
|
| |
|
|
Model no.:
|
Data logger - Logg. - 8
Temp. Scanner - Scan - 8. |
No. Of channel:
|
Max. 8 channels. |
Input:
|
Fixed input type Factory settable for thermocouples (J,K,R,S,T,E,B,N),RTD (PT-100),
4-20mA,0-1VDC Etc. Thermocouples (J,K,R,S,T,E,B,N) can be set at field through Keyboard. |
Display:
|
4 Digits of 0.56” height 7 seg. display for process value display
1 Digits of 0.56” height 7 seg. display for channel no. Display. |
Settings:
|
4 Soft touch Keys on front panel for parameter programming. |
|
|
L.E.D. Indication:
|
8 L.E.D.s for alarm indication,AL1 & AL2 |
Other indications:
|
» Temp. sensor Break or open indication on display.
» For 4-20mA & 0-1VDC Linear input under range and over range indication.
» Built in temperature reading in °C or °F User selectable. |
Alarm:
|
» 2 independent set points with hysterisis individual for each channels with 2 common relay output of 1 NO/C/NC Relay contact rated 230V/5A for relay1(AL1) & Relay 2 (AL 2).
» Optional individual relay output can br given for each channel with external relay module.
» Programmable LATCH and NON-LATCH facility for common relay and LED indication. |
| Linearisation: |
Very high accuracy 0.3% with software linearisation. |
| Scan Rate: |
Field programmble channel scan time 1 to 59 seconds for display. |
Compensation:
|
» Automatic Cold Junction Compensation for all thermocouples.
» Automatic Wire Length Compensation for long wire RTD input. |
| Comm.with PC: |
RS-232/RS-485 Serial port with MODBUS RTU PROTOCOL. |
| Dimensions: |
(96W x 96H x 170D)mm. |
| Cutout: |
(92W x 92H)mm . |
|
| |
| Optional Features of Data Logger |
Real Time Clock:
|
Nonvolatile memory EEPROM and battery back up for RTC (Real Time Clock). |
Printout facility:
|
» Along withRS-232/RS-485 Serial port with MODBUS RTU PROTOCOL,
Direct Printout on 80 Column Dot Matrix Printer by 25 pin
parallel port without need of computer (optional) can be given.
» Field programmable print interval 5 to 9999 seconds. |
| Data storage: |
5000 readings per channel can be stored for all 8 channels available. |
| Data Security: |
EEPROM (Nonvolatile),ensures data retention for 10 years. |
Software:
|
Windows based Data Acquisation software (optional) |
|
| |
| Application |
• Pharmaceutical
• Online Recording for oven &BOD ,Incubator, Humidity Chamber.
• Water pumping station, Water purification & Treatment Plant.
• Iron and Steel Industries for soaking pit oxygen plant, smelter plant.
• Chemical & petrochemical industry. |
|
| |
|
| |
|
|